NotesFAQContact Us
Collection
Advanced
Search Tips
Back to results
Peer reviewed Peer reviewed
Direct linkDirect link
ERIC Number: EJ1294661
Record Type: Journal
Publication Date: 2021-Mar
Pages: 11
Abstractor: As Provided
ISBN: N/A
ISSN: ISSN-1092-4388
EISSN: N/A
Available Date: N/A
Short-Term Test-Retest Reliability of Contralateral Suppression of Click-Evoked Otoacoustic Emissions in Normal-Hearing Subjects
Keppler, Hannah; Degeest, Sofie; Vinck, Bart
Journal of Speech, Language, and Hearing Research, v64 n3 p1062-1072 Mar 2021
Purpose: The objective of the current study was to investigate the short-term test-retest reliability of contralateral suppression (CS) of click-evoked otoacoustic emissions (CEOAEs) using commercially available otoacoustic emission equipment. Method: Twenty-three young normal-hearing subjects were tested. An otoscopic evaluation, admittance measures, pure-tone audiometry, measurements of CEOAEs without and with contralateral acoustic stimulation (CAS) to determine CS were performed at baseline (n = 23), an immediate retest without and with refitting of the probe (only CS of CEOAEs; n = 11), and a retest after 1 week (n = 23) were performed. Test-retest reliability parameters were determined on CEOAE response amplitudes without and with CAS, and on raw and normalized CS indices between baseline and the other test moments. Results: Repeated-measures analysis of variance indicated no random or systematic changes in CEOAE response amplitudes without and with CAS, and in raw and normalized CS indices between the test moments. Moderate-to-high intraclass correlation coefficients with mostly high significant between-subjects variability between baseline and each consecutive test moment were found for CEOAE response amplitude without and with CAS, and for the raw and normalized CS indices. Other reliability parameters deteriorated between CEOAE response amplitudes with CAS as compared to without CAS, between baseline and retest with probe refitting, and after 1 week, as well as for frequency-specific raw and normalized CS indices as compared to global CS indices. Conclusions: There was considerable variability in raw and normalized CS indices as measured using CEOAEs with CAS using commercially available otoacoustic emission equipment. More research is needed to optimize the measurement of CS of CEOAEs and to reduce influencing factors, as well as to make generalization of test-retest reliability data possible.
American Speech-Language-Hearing Association. 2200 Research Blvd #250, Rockville, MD 20850. Tel: 301-296-5700; Fax: 301-296-8580; e-mail: slhr@asha.org; Web site: http://jslhr.pubs.asha.org
Publication Type: Journal Articles; Reports - Research
Education Level: N/A
Audience: N/A
Language: English
Sponsor: N/A
Authoring Institution: N/A
Grant or Contract Numbers: N/A
Author Affiliations: N/A